Montag, 3. März 2014

Roofing Rancho Penasquitos- Guide in Choosing a Roofing for your House

Choosing the right one to replace old roof - or to identify the best choice for a new building - not an easy task. Ideal for roof of a building may be the worst option for another just down the street. This is because no two buildings are exactly alike, even if they are similar. So how do you choose a new home, given all the choices in the market? You can start by asking several questions before choosing the roof, roofing contractor or manufacturer.



1. What is the mission of this building?



Before calls are made to contractors and manufacturers of roof, the element of the first address is the mission statement of the company in relation to the building.



Whether you are building new facilities or property management, you want to be sure that the roof systems to provide the performance you expect that you choose. More often than not, the building itself to dictate the appropriate extension roof.



You should know as much about the building and its possible future. The business plan to maintain this building as part of its real estate assets for the next 10 to 20 years? Are there plans to expand it in the near future, or to change its use? What are the current and future occupation, isolation requirements, priorities and programs of aesthetic equipment maintenance, even on the roof?



Declaration of these and other mission is to help shape responses to the types of roof and take into account the amount of the capital budget is really necessary for the job.



Start the questions What is the building will be used. If the building specs, maybe you need just a basic roof. But if the body has a specific purpose, like an airline reservation center with computers, is seen from the roof, then the options are very different.



For example, as more companies move in the direction of the operation 24 hours a day, seven days a week to satisfy customers worldwide, data center has never spring a leak in the roof. Water on the computer systems usually spells disaster.



A special series of cooling-dominated climates. It will help to save the roof air-conditioning and to address other key issues? It 'part of the comprehensive program of energy? There's growing concern about heat island city. Reflective white roofs are of interest to the regions, a couple of reasons. They keep the building cooler, reducing air conditioning costs, and also to reduce the heat load to the environment.



2. What are the physical and other affect the roofing system of choice?



After identifying the goals and mission of the institution, it's time to evaluate the building itself. You need to start looking at the building location and characteristics of its surroundings. You should investigate local building codes, climate, topography - also the direction the building faces.



The physical characteristics of the building are also crucial: size, shape, design, size and age.



You must also consider the building materials used to construct the facility and the location of plumbing and fire protection equipment, especially if one or both of these are partially or wholly located on the roof.



When it comes to replacing the roof, you have to list the attributes of the roof surface itself. It is best to detail the size of the roof shape, slope, construction of the bridge, edge detail, cornice, roof access and the existing roof system. Along with this basic information, as to why the original tag is no longer sufficient.



That third option flexible membrane cover are available?



SPRI, the association representing sheet membrane and component suppliers for industrial roofing business, identifies three broad types of membranes: thermosets, thermoplastics and modified bitumen.



Thermoset membranes are made of rubber polymers. The most common are EPDM, often referred to as "rubber roofing." These membranes are well suited to withstand the potentially damaging effects of sunlight and chemicals commonly found on roofs. They are easily identifiable on the roof. Just look at the seams. Thermoset membranes requires liquid glue or tape to form a seal at the overlaps.



Thermoplastic membranes are based on plastic polymers. The most common is PVC, which is made flexible by adding plasticizers. Thermoplastic membranes have seams that are usually formed by thermal welding. Most thermoplastic membranes are manufactured with a backing layer, usually polyester or fiberglass for added strength and dimensional stability.



Hypalon thermoplastic begins as a thermoplastic, but hardens with time to become a thermosetting. Like other thermoplastics, Hypalon materials are heat-sealed seams.



Another hybrid thermoplastic is a thermoplastic poly-olefin (TPO), which combines the properties of EPDM and PVC. TPO membranes do not improve after exposure to the elements and keep hot air weldable throughout their service life. Most of TPO membranes are reinforced polyester, fiberglass or a combination of both, but not reinforced TPO membranes are available.



Modified bitumen membranes included in the formulation and prefabrication advantages of a flexible membrane roof in some traditional installation techniques used in urban coverage. Modified bituminous membranes are produced in the factory, which is a polymer modified asphalt, rubber or plastic increases flexibility, and combined with reinforcement for strength and stability.



4. What type of membrane and cleats are best for construction?



Many factors determine the best system for a particular building. For most buildings, there are a number of options and benefits must be weighed against the mission statement of the institution. The decision should not be based solely on the basis of costs. Other important considerations for the membranes are the building height, wind exposure, the expected traffic and the aesthetics of the cover.



The mounting system also depends on the specific characteristics of the building. If the roof deck can support the weight, a roof ballast to be the best solution. But if the roof slope is greater than 2 inches per foot, this system may not be appropriate. There are other restrictions on ballast systems, such as the height of the roof, near the coast and other areas of high wind, and the availability of ballast water.



A bridge made of steel or wood easily accepts a tie makes a good substrate for the membrane mechanically. These systems can be designed to provide the necessary resistance to the wind are not known and limitations of the slope.



Another alternative is the system fully complied with when the membrane is attached to the prepared surface using a particular adhesive. According to the membrane, the adhesive solvent or water-based or asphalt. The finished surface of a living roof is smooth.



For those interested in the aesthetics of the building, the membranes of color can make a valuable contribution to the appearance of the building.



5. T for all roofing materials delivered on site to carry the UL label?



Otherwise, you can specify that it should. It's the only way you can ensure that roofing materials installed on your roof are the same materials tested by Underwriters Laboratories. In addition, make sure the roof you buy or specify which include insulation, UL listed and labeled. Use insulation other than what has been tested with the roofing membrane may void the UL classification. If the UL Building Materials Directory does not list the roofing system, you are sold, insist on control of the classification as a photocopy of a letter of UL approval.



Make sure the product is the real product has been tested. If you do not want something that is similar but not identical. Search the site with the label and make sure that all system components have been tested together. You want to test the insulating film, that you own the building.



6. The system requires assessment of wind loads?



Wind damage elevation can be long and costly. Accepted as an industry standard, the American Society of Civil Engineers Standard 7-95, "Minimum design loads for buildings and other structures" can be used to determine the wind zone for the property. Wind increased testing, as conducted by Factory Mutual and Underwriters Laboratories, can be used to determine that the selected roof system meets or exceeds local wind uplift.



7. The more ready for the dead weight load of the roof structure of the system?



Selecting repair, the facility executive to pay attention to the carrying capacity of the roof deck to ensure the possibility of flexible membrane is selected correctly. In new construction can save money by structural steel is often achieved by installing a membrane system more flexible.



A ballast EPDM or thermoplastic roof may require more than 1,000 pounds per 100 square feet, while a membrane mechanically fastened or fully adhered thermo-setting or thermoplastic weighs 33 pounds per 100 square feet. A system can often easier re-roof directly to your existing roof, while the heavier may require tearing the old roof and start over. But weight is a consideration when choosing a roofing membrane and the attachment system. Ballasted roof may be the best choice for a particular installation. Facility managers must ensure that all relevant considerations, including weight, are taken into account in decision making.



8. What are the strengths and assets of the financial roofing contractor you are considering?



Roofs must be chosen with great care. The introduction of roofing materials and new techniques applied in the past 10 years has led to many changes. A roofing professional should be familiar with different types of roofing systems, so you can make the best decision for your business based on your budget.



Ask the contractor if his company is a member of a local authority, trade association, state, regional or national level. Contractors involved in professional associations are generally better informed about the latest developments and challenges of their industry.



They insist that the contractor will provide copies of insurance certificates that verify workers compensation and general liability. Make sure that these coverages are in effect for the duration of your roofing job. If the contractor is properly insured, your company, as owner, may be responsible for accidents that occur on the property. Also check out the licensing requirements in your state and if the contractor is bound by an insurance company.



The installation of roofing systems varies considerably different. Teaching and learning are key elements in the installation of roofing systems. Make sure the roofer you choose has received detailed training and ongoing on the installed system.



A rule of thumb is whether the contractor has installed at least 100,000 square feet of the system you want in the last 18 months. Also make sure that the contractor is approved by the manufacturer to install this specific system.



The quality of work is crucial to good performance roof. The National Roofing Contractors Association offers a guide to professional roofing choice. In addition, many manufacturers have approved construction programs with specific skills to be met by roofers, before approval.



9. What is justified, and by whom?



There are two basic categories of covered warrants. Ensuring that the general contractor, covering manufacturing. The manufacturer's warranty covers at least the materials, but include many additional topics. Even if the manufacturer's warranty is very broad, will not protect you completely if the roof is installed properly.



Carefully read and understand any roofing warranty offered and watch for provisions that void. For example, it is almost impossible to avoid any standing water. Accumulated water can be caused by a leaking roof or blocked the bending of the roof terrace between the two columns. Proper roof maintenance can help ensure that the guarantee is valid. Be aware of the language of security that will void the warranty.



Most professional contractors to provide coverage for periodic checks during the year. These controls help to ensure that the project complies with the standards specified in the warranty. A typical maintenance program consists of a detailed visual inspection of the roof system, flashing, insulation and related components to identify potential problem areas.



More important than the guarantee is the right type of flexible membrane roof of your building, in the first place. If the roof is properly designed and installed to meet the needs of your body, building or geographical factors, and the guarantee will cover these needs, you probably will not enjoy the flexible membrane roof for many years after the original warranty expires.



10. When the roof is installed, then what is the service and educational programs are available in facilities management team?



Seminars offered by industry organizations such as the roof of SPRI and manufacturers can be of great value to the team the roof to expand their understanding of the types of commercial roofing system, the installation process and maintenance considerations. Specific courses that can help owners and facility managers to learn about different roofing systems, materials and components, insulation and accessory products, elements of the roof design, contractor selection, guarantees and maintenance considerations.


1 Kommentar:

  1. Thank you for sharing valuable information. Nice post. I enjoyed reading this post. The whole blog is very nice found some good stuff and good information here Thanks..Also visit my page Industrial Roofing

    AntwortenLöschen